| DOUBLE SKIN
OPERATION MODES
WINTER SEASON
SOLAR HARVEST
The cavity acts as a thermal buffer zone between
the building and the outside. This reduces space-heating requirements
as both conduction and infiltration gains are reduced. Good
solar penetration is achieved and acoustic protection is offered.
FRESH AIR PIPE
The cavity acts as a thermal buffer zone between
the building and the outside. This reduces space-heating requirements
as both conduction and infiltration gains are reduced. Pre-heating
the fresh air in the cavity prior to use can serve to reduce
energy costs associated with this activity. Good daylight
penetration is achieved and services can be relocated to the
perimeter of the building increasing net lettable space. Acoustic
insulation is given.
MID SEASON
The openable skins allow a natural ventilation
strategy to be adopted. Fresh air is taken without energy
expenditure in heating/cooling and provision and extraction.
Blinds provide solar exclusion/harvest as required. Good daylight
penetration is achieved and services can be relocated to the
perimeter of the building increasing net lettable space. Acoustic
insulation is reduced.
SUMMER SEASON
SEALED SKINS
Blinds within the cavity provide excellent
solar control. Space cooling loads are reduced, increasing
net lettable areas and reducing capital expenditure. Exhaust
air is extracted via the cavity to remove heat gains. Good
daylight penetration is achieved and services can be relocated
to the perimeter of the building increasing net lettable space.
Acoustic insulation is given.
VENTED SKINS
Blinds within the cavity provide excellent
solar control. The openable skins allow a natural ventilation
strategy to be adopted. Night-time cooling is possible. Fresh
air is taken without energy expenditure in cooling, supply
or extract. Blinds provide solar control. Good daylight penetration
is achieved. Cooling plant is no longer required, reducing
capital expenditure and increasing net lettable space.
|